Changing the communication settings (axu) – Vaisala WXT520 User Manual

Page 65

Advertising
background image

Chapter 6 ________________________________________________________ Connection Options

VAISALA_______________________________________________________________________ 63

Changing the Communication
Settings (aXU)

Make the desired setting with the following command. Select the
correct value/letter for the setting fields, see

Setting Fields on page 61

.

See also the examples.

Command format in ASCII and NMEA 0183:

aXU,A=x,M=x,C=x,I=x,B=x,D=x,P=x,S=x,L=x<cr><lf>

Command format in SDI-12:

aXXU,A=x,M=x,C=x,I=x,B=x,D=x,P=x,S=x,L=x!

where
A, M, C, I,
B, D, P, S,L

=

The communication setting fields, see

Setting Fields

on page 61

.

x

=

Input value for the setting

<cr><lf>

=

Command terminator in ASCII and NMEA 0183

!

=

Command terminator in SDI-12

NOTE

When changing the serial interface and communication protocol, note
the following:

Each serial interface requires its specific wiring and/or jumper settings
described in

Chapter 5, Wiring and Power Management, on page 43

.

Change first the serial interface field C and then the communication
protocol field M.

Changing the serial interface to SDI-12 (C=1) will automatically
change the baud settings to 1200, 7, E, 1 and the communication
protocol to SDI-12 (M=S).

NOTE

Reset the transmitter to validate the changes of communication
parameters by disconnecting the service cable or using the Reset
(aXZ)
command, see

Reset (aXZ) on page 66

.

Advertising