54

Network Tab

Enter Vlan ID number (Required): Enter the desired Vlan ID interface number in the field provided. The valid range is 
0‐4096 and each interface must be uniquely numbered. The final Vlan ID will then be in the form ethx.y where x is the 
root interface number and y is the vlan ID number. Your Network Administrator should be able to provide guidance as 
to an appropriate value.

Enter IP Address (Required): Enter the desired interface IP Address into this field. This address should have been pro‐
vided by your Network Administrator.

Enter Netmask: Enter the desired Netmask for the Vlan interface in the field provided. You Network Administrator 
should be able to provide an appropriate number.

Click on the Finish button and you will be directed to the Ethernet Interface dialog window and the Interface 
Aliases table will be populated with the entered data.

Reboot: Will restart the system and apply all the settings upon reboot.

Revert: Will revert the settings in the dialog window back to the previous saved settings.

Save: The interface will not be activated or deactivated until the device is rebooted. This allows for other configuration 
changes to be made to the device which can be committed at a later time.

Apply: The current settings will be saved and the interface will either be activated or deactivated immediately. If the 
interface was already active, then it will be deactivate and reactivated using the configured settings just saved. If you 
were connected to the Web UI via this interface, an attempt will be made to re‐connect to it using the new settings, 
when possible.

Applying new settings to the interface may result in disconnection, requiring reconnection using alternate methods.

Incomplete or incorrect network settings could render the device incommunicable and may require being able to connect 
either to the device directly or via the network to which it is attached.

Note: To work with the eth1 Interface, follow the steps documented for eth0.