Diagnosis and error treatment

Fault

Cause

Possibilities

Motor does not
move

Motor cable defective

Check motor cable

move

Brake not activated

Open brake by applying 24ĂV DC

Supply voltage is below 21 V DC
or above 51 V DC

Measure supply voltage

Motor loses
steps

Motor cannot give torque
required

Check characteristic curve of
motor, check which torque can
be given

Frequency too high

Reduce frequency (controller)

10

Technical specifications

Motor

MTRE−ST42−48S−A A

MTRE−ST42−48S−AB

Rated voltage

24 ... 48 V DC +5/−10 %

Current setting

0.3 ... 1.2 A (Steps of 0.2 A)

Holding torque M

0.34 Nm

Step angle

ö

1.8°

±5 %

Moment of inertia of drive J

0.068 kg cm

2

0.07 kg cm

2

Holding torque of brake M

ć

0.4 Nm

Output of brake P

ć

6 W

Voltage of brake V

ć

24 V

Radial shaft load N

18 N

18 N

Axial schaft load N

7 N

7 N

Weight of product m

0.45 kg

0.55 kg