Operator

36

1

word

Product

38

1

word

Client

40

1

word

Packaging

42

1

word

Source warehouse

44

1

word

Destination warehouse

46

1

word

Formulation

48

1

word

basic command – Setting a bit causes carrying out a task as specified

in a below table:

Command bit Command

0

Zero platform

1

Tare platform

3

Clear statistics

4

Save / Print

5

Start

6

Stop

Example:

0000 0000 0010 0000 – the command carries out process start

complex command

- Setting a bit causes carrying out a task as

specified in a below table:

Command bit Command

0

Setting tare value of a weighing platform

1

Setting the value of LO limit of a weighing platform

2

Setting outputs status

3

Setting the value of MIN threshold

4

Setting the value of MAX threshold

Notice:
A complex command requires setting an appropriate parameter
(addresses from 4 to 48. – see table “List of parameters in a complex
command”).