Module of analogue outputs, Technical specification, The way of installing inside pue hy – RADWAG HTY 60/H5/K Multifunctional Scales User Manual
Page 206

206
J3 – WE 8 module
J3 – AN module
J10 – PK1
Relay module
J11 – DP2 module
37.1. Module of Analogue Outputs
Module of analogue outputs
Module accessible in three configurations:
•
Voltage output AN 0-10V
•
Current output AN 4-20mA
•
Current output AN 0-20mA
37.1.1. Technical specification
Work modes
4 - 20mA , 0 - 20mA, 0 - 10V
Resolution
16 bit
Current output resistance
<500
Voltage output resistance
>400
Power supply
24V DC (12 - 30V DC) max 40mA
37.1.2. The way of installing inside PUE HY
These modules are intended to mount inside PUE HY. They need to be
connected to the 10-pin J3 connector. For all configurations of AN, there
is a gland installed on the back wall of the housing. A 3-meter shielded
cables are led out via the gland. Wires should be free from insulation.
- HTY 60/H4/K Multifunctional Scales HTY 60/C2/K Multifunctional Scales HTY 6/H2/K Multifunctional Scales HTY 6/F1/K Multifunctional Scales HTY 300/H6/K Multifunctional Scales HTY 300/H5/K Multifunctional Scales HTY 300/C3/K Multifunctional Scales HTY 300/C2/K Multifunctional Scales HTY 30/H3/K Multifunctional Scales HTY 30/F1/K Multifunctional Scales HTY 30/C2/K Multifunctional Scales HTY 3/H1/K Multifunctional Scales HTY 150/H6/K Multifunctional Scales HTY 150/H5/K Multifunctional Scales HTY 150/H4/K Multifunctional Scales HTY 150/H3/K Multifunctional Scales HTY 150/C3/K Multifunctional Scales HTY 150/C2/K Multifunctional Scales HTY 15/H3/K Multifunctional Scales HTY 15/H2/K Multifunctional Scales HTY 15/F1/K Multifunctional Scales HTY 60/H3/K Multifunctional Scales