h. Switching Frequency Across Dim Range
From the equations below and setting the OTP registers as follows, the switching frequency across the dim
range can be calculated. A sample plot of the switching frequency across dim values is shown in Figure 7.

The frequencies in regions A, B, C, and D are governed by Equations 44, 45, 46 and 47, respectively.
Transitions between connecting regions are the result of simple inequalities. The following four equations do
not include the effect of a color system. Equations 44 through 47 must be adjusted after the color system has
been designed.
Frequency in Region A
In Region A, the system operates in CRM, and the period TT

A

is calculated using Equation 44:

where,

TT

A

> TT

B

at the given dim level

dim = The 12-bit dim level provided by the boost stage

Frequency in Region B
In Region B, the system operates in DCM, but the peak current remains the same. Period TT

B

is calculated

using Equation 45:

where,

TT

B

< 50

s

TT

B

> TT

A

0

5

10

15

20

25

30

35

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

Frequency (kHz

)

Dim

D

C

B

A

Figure 7. Dual Pulses Switching Frequency

TT

A

0.5

TT

dim1

TT

dim2

+

TT

dim1

TT

dim2

+

2

4 T

res

+

+

2

=

[Eq. 44]

TT

dimx

2 L dim I

MODEx

 

 N

2

V

MODEx

 1 D

MODEx

=

[Eq. 45]

TT

B

TT

FREQ

dim

--------------------

=