j. External Overtemperature Protection
The external negative temperature coefficient (NTC) thermistor reference is a Murata NCP18WF104J03RB.
This NTC is 100k

 with a Beta of 4275. If the temperature exceeds 95°C, R

NTC

is approximately 6.3k

 and

resistor R29 is 14k

, so the eOTP pin has a total resistance of 20.3k. Solving Equation 75 for

CODE

TEMPeOTP

:

The eOTP circuit initiates a protective dimming action at 125°C. A temperature of 125°C corresponds to a
thermistor resistance equal to 2.5k

 plus resistor R18 equal to 14k which presents a resistance of 16.5k

at pin eOTP, reaching the point at which a thermal shutdown fault intervenes. Solving Equation 75 for
CODE

TEMPShutdown

:

The OTP settings are configured using the following:

1. Set bit EEOTP in register Config47 at Address 79 to ‘0’ to enable external overtemperature protection
2. Set bit BOOST_ON in register Config53 at Address 85 to ‘0’, which enables boost after a eOTP

measurement check for Temp

NTC

> Temp

Wakeup

3. Set bits eOTP[4:0] in register Config59 at Address 91 to ‘11110’, which configures the 8-bit code value

CODE

TEMPeOTP

to 200

4. Set bits WAKEUP[3:0] in register Config46 at Address 78 to ‘0101’, which configures the 8-bit code

value CODE

TEMPWakeup

to 220

5. Set bits SHUTDWN[3:0] in register Config58 at Address 90 to ‘0101’, which configures the 8-bit code

value CODE

TEMPShutdown

to 240

6. Set bits EOTP_FLP[2:0] in register Config55 at Address 87 to ‘100’ to set the time constant of the first

(faster) low-pass filter used for filtering the coarse 8-bit ADCR temperature to 1.866s

7. Set bits EOTP_SLP[2:0] in register Config55 at Address 87 to ‘110’ to set the time constant of the

second (slower) low-pass filter used for filtering the coarse 8-bit ADCR temperature to 1min

8. Set bits RATE[1:0] in register Config44 at Address 76 to ‘11’ to set the dimming rate for the external

overtemperature protection feature to 32 dims per temperature code above CODE

TEMPeOTP

9. Enable the second-stage dim level adjustment process by setting bit DIM_TEMP in register Config58 at

Address 90 to ‘1’

10. Set bits LOW_SAT[2:0] in register Config58 at Address 90 to ‘001’ to configure the lower saturation limit

CODE

LOWSAT

to 10

11. Set bits HI_SAT[2:0] in register Config59 at Address 91 to ‘100’ to configure the higher saturation limit

CODE

HISAT

to 160

k. Internal Overtemperature Protection
The OTP settings are configured using the following:

1. Set bit IOTP in register Config47 at Address 79 to ‘0’ to enable the internal overtemperature protection
2. Set bit IOTP_SAMP in register Config48 at Address 80 to ‘1’ to sample the internal temperature sensor

at a slow rate when not in a iOTP fault

Step 16) Clamp Circuit
Clamp load resistors R9 and R11 must each be 2k

2W resistors for 120V systems. This value has been

validated for optimal dimming performance.

CODE

TEMPeOTP

4M

R

NTC

R

S

+

--------------------------------

4M

6.3k

 14k

+

------------------------------------------

197

=

=

=

[Eq. 142]

CODE

Shutdown

4M

R

NTC

R

S

+

--------------------------------

4M

2.5k

 14k

+

------------------------------------------

242

=

=

=

[Eq. 143]