3.24 GENERATOR

Every 250 hours

Every 250 hours of operation, check the drive belt for
proper tension.

Every 500 hours

Every 500 hours of operation, service the generator
brushes and slip rings. Hostile environments may require
more frequent service.

Every 500 hours of service, blow out the inside of the gen-
erator. If operating in a hostile environment, clean
monthly.

Table 3-6. Coupling Port Information Table

Port

No.

Port
Size

Description

Operating

Pressure
PSI (Bar)

Proof

Pressure
PSI (Bar)

1

-12

Return

250 (17)

375 (26)

2

-10 Steer/Axle Extend

(Pressure)

3000 (207) 4500 (310)

3

-10

Drive A

5000 (345) 7500 (517)

4

-10

Drive B

5000 (345) 7500 (517)

5

-10

Drive A (Osc. Axle Lock)

5000 (345) 7500 (517)

6

-10

Drive B (Osc. Axle Lock)

5000 (345) 7500 (517)

7

-12

Case Drain

250 (17)

375 (26)

1/2 in.

(13 mm)