Installation, Installation -79 – JLG 1250AJP Service Manual User Manual

Page 319

Advertising
background image

SECTION 4 - BOOM & PLATFORM

3121171

– JLG Lift –

4-79

16. If the main boom angle sensors are calibrated and

operating properly, the control system will now allow
main lift up/down below main boom angles of +65°.

17. Activate main lift and elevate the boom enough to

gain access to remove the main lift cylinder.

18. Use a crane or other suitable supporting device to

support the weight of the main boom assembly.

NOTE: The main boom assembly weighs approximately

6500 lbs. (2950 kg).

19. Put a nylon strap capable of supporting the weight

of the lift cylinder around the cylinder.

NOTE: The main lift cylinder weighs approximately 785 lbs.

(356 kg).

20. At the barrel end of the cylinder, place blocking

under the lower link and between the upper and
lower links so they do not drop when the pivot pin is
removed.

21. Remove the retaining bolt, keeper pin, and pivot pin

securing the barrel end of the lift cylinder to the
lower link.

22. At the rod end of the cylinder, remove the retaining

bolt, keeper pin, and pivot pin securing the rod end
of the lift cylinder to the boom.

23. Remove the cylinder from the machine.

Installation

1. Using an adequate lifting device, position the main

lift cylinder in place on the machine.

NOTE: The main lift cylinder weighs approximately 785 lbs.

(356 kg).

2. Install the retaining bolt, keeper pin, and pivot pin

securing the barrel end of the lift cylinder to the
lower link.

3. If necessary, refer to Removal and use the analyzer

Service Mode to cycle the cylinder in and out several
times to purge air from the cylinder.

4. At the rod end of the cylinder, install the retaining

bolt, keeper pin, and pivot pin securing the rod end
of the lift cylinder to the boom. It may be necessary
to use the analyzer Service Mode to align the pin.

5. Remove the blocking placed under the lower link

and between the upper and lower links during
removal.

6. Refer to Removal, and use the analyzer Service

Mode procedure to lower the boom.

Advertising