SECTION 6 - JLG CONTROL SYSTEM

3121171

– JLG Lift –

6-29

JIB SWING:

ACCEL X.Xs

Displays/adjusts jib swing acceleration

0.1 to 5.0 sec

1.5

DECEL X.Xs

Displays/adjusts jib swing deceleration

0.1 to 3.0 sec

0.5

MIN LEFT XX%

Displays/adjusts minimum jib left speed.
Same as Creep speed

0 to 65%

40

MAX LEFT XXX%

Displays/adjusts maximum jib left speed

0 to 100%

70

42-47 (125)

MIN RIGHT XX%

Displays/adjusts minimum jib right speed.
Same as Creep speed

0 to 65%

40

MAX RIGHT XXX%

Displays/adjusts maximum jib right speed

0 to 100%

70

42-47 (125)

GROUND MODE:

m. LIFT UP XXX%

Displays/adjusts fixed main lift up speed

0 to 100%

60

m. lift DN XXX%

Displays/adjusts main lift down speed

0 to 100%

60

SWING XXX%

Displays/adjusts fixed swing speed

0 to 65%

45

BASKET LVL XXX%

Displays/adjusts fixed basket level speed

0 to 100%

75

BASKET ROT XXX%

Displays/adjusts fixed basket rotate speed

0 to 100%

75

MAIN TELE XXX%

Displays/adjusts fixed main telescope
speed

0 to 100%

65

TOWER TELE XXX%

Displays/adjusts fixed tower telescope
speed
Not displayed if TOWER TELE=NO

40 to 40%

40

T. LIFT UP XXX%

Displays/adjusts fixed tower lift up speed
Not displayed if TOWER LIFT=NO

40 to 40%

40

T. LIFT DN XXX%

Displays/adjusts fixed tower lift down
speed
Not displayed if TOWER LIFT=NO

40 to 40%

40

JIB (U/D) XXX%

Displays/adjusts jib lift speed
Not displayed if JIB = 0

0 to 100%

60

JIB (L/R) XXX%

Displays/adjusts jib swing speed
Displayed if JIB = 2

0 to 100%

70

GEN SET/WELDER:

Engine XXXX RPM

Control generator/welder RPM. Not dis-
played if GEN SET/WELDER = 0

1200-2800

1800

NOTES: Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
Stop watch should start when the function is activated.Not with the controller or switch.
Unless noted, function speeds should be measured from platform.
Platform speed knob must be at full speed (fully clockwise).
All test should be done with the oil temp above 100° F (38° C).

4150517-4

Table 6-4. Machine Personality Settings and Speeds