SECTION 4 - BOOM & PLATFORM

3121171

– JLG Lift –

4-65

16. Enter code 95268. The analyzer will read:

WHEN THE STABILITY CONTROL IS OFF THE MACHINE WILL TIP
IF USED INCORRECTLY.

17. Press the ENTER key to acknowledge the stability

control is turned off. The analyzer should read:

18. The control system will now allow only tower tele-

scope using the tower lift switch on the ground con-
sole.

BEFORE CONTINUING WITH THIS PROCEDURE, DOUBLE CHECK
ALL SUPPORTING DEVICES AND MID BOOM RESTRAINING
CHAIN.

19. Extend the tower fly section no more than necessary

to gain access to the telescope cylinder retaining pin
(about 5.5 ft. [1.7 m]). When access is gained to the
telescope cylinder retaining pin, remove the four
shoulder bolts and two snap rings that hold it in
place and remove the telescope cylinder retaining
pin.

20. At the rear of the tower boom, tag and disconnect

the wires going to the angle sensors. Remove the
bolts and washers that fasten the angle sensors to
the boom section and remove the angle sensors.