Machine personality settings and speeds -26 – JLG 1250AJP Service Manual User Manual

Page 458

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-26

– JLG Lift –

3121171

Table 6-4. Machine Personality Settings and Speeds

Submenu

(Displayed on

Analyzer 1st

Line)

Parameter

(Displayed on Analyzer 2

nd

Line)

Description

Range

DEFAULT

VALUES

TIME RANGE

(SEC) (SEE
Section 6.9

FOR MACHINE

ORIENTATION

WHENSETTING

SPEEDS)

DRIVE:

ACCEL X.Xs

Displays/adjusts drive acceleration

0.1 to 5.0 sec

2.0

DECEL X.Xs

Displays/adjusts drive deceleration

0.1 to 3.0 sec

1.3

MIN forward XX%

Displays/adjusts minimum forward drive
speed

0 to 35%

1

MAX forward XXX%

Displays/adjusts maximum forward drive
speed

0 to 100%

100

40-48 (see

orientation)

MIN reverse XX%

Displays/adjusts minimum reverse drive
speed

0 to 35%

1

MAX reverse XXX%

Displays/adjusts maximum reverse drive
speed

0 to 100%

100

40-48 (see

orientation)

ELEV. MAX XX%

Displays/adjusts maximum drive speed
NOTE: used when elevation cutout
switches are limiting maximum speed

0 to 50%

25

93-104 (see

orientation)

CREEP MAX XX%

Displays/adjusts maximum drive speed
NOTE: used when creep switch on pump
pot is active

0 to 50%

35

79-87 (see

orientation)

STEER:

max SPEED XXX%

Displays/adjusts maximum steer speed.

0 to 100%

100

MAIN LIFT:

ACCEL X.Xs

Displays/adjusts main lift acceleration

0.1 to 5.0 sec

1.0

DECEL X.Xs

Displays/adjusts main lift deceleration

0.1 to 3.0 sec

1.0

MIN Up XX%

Displays/adjusts minimum main lift up
speed

0 to 60%

1

MAX UP XX%

Displays/adjusts maximum main lift up
speed

0 to 60%

60

57-69 (see

orientation)

CREEP UP XX%

Displays/adjusts maximum main lift up
speed
NOTE: used when creep switch on pump
pot is active

0 to 65%

35

MIN DOWN XX%

Displays/adjusts minimum main lift down
speed

0 to 60%

1

MAX DOWN XXX%

Displays/adjusts maximum main lift down
speed

0 to 60%

60

59-70 (see

orientation)

CREEP DOWN XX%

Displays/adjusts maximum main lift down
speed
NOTE: used when creep switch on pump
pot is active

0 to 75%

35

Advertising