JLG 1250AJP Service Manual User Manual
Page 26

SECTION 1 - SPECIFICATIONS
1-8
– JLG Lift –
3121171
C: Wheel Drive Hub - Reggiana Riduttori (S/N
134389 to Present)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every
1200 hours of operation
Comments - Place Fill port at 12 o’clock position
and Check port at 3 o’clock position. Pour lubri-
cant into fill port until it just starts to flow out of
check port.
5. Hydraulic Return Filter
(See Figure 1-2., Hydraulic Return Filter Condition Indicator
- Prior to S/N 139396 and Figure 1-3., Hydraulic Return Fil-
ter Condition Indicator - S/N 139396 to Present)
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300
hours
thereafter or as indicated by condition indicator.
6. Hydraulic Charge Filter
or
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300
hours
thereafter or as indicated by condition indicator