ENVELOPE SENSORS:

TWR LEN1 (X.X)"

Displays the measured value of tower length sensor #1

TWR LEN2 (X.X)"

Displays the measured value of tower length sensor #2

TWR ANGL1 (XX.X)

Displays the measured value of tower angle sensor #1

TWR ANGL2 (XX.X)

Displays the measured value of tower angle sensor #2

CYL ANGL (XX.X)

Displays the measured value of cylinder angle sensor #2

MN ANGL1 (XX.X)

Displays the measured value of main angle sensor #1 to the tower

MN ANGL2 (XX.X)

Displays the measured value of main angle sensor #2 to the tower

TO GRAV MN ANGL L (XXXX)

Displays the measured value of lowest value main angle sensor to gravity

TO GRAV MN ANGL H (XXXX)

Displays the measured value of largest value main angle sensor to gravity

A/D T LEN1 (X)

Displays the analog to digital counts of tower length sensor #1

A/D T LEN2 (X)

Displays the analog to digital counts of tower length sensor #2

A/D ANG1 (XX.X)

Displays the analog to digital counts of tower angle sensor #1

A/D ANG2 (XX.X)

Displays the analog to digital counts of tower angle sensor #2

A/D CYL (X)

Displays the analog to digital counts of cylinder angle sensor

MN ANG A/D SNSR1 (XXXX)

Displays the analog to digital counts of main angle sensor #1

MN ANG A/D SNSR2 (XXXX)

Displays the analog to digital counts of main angle sensor #2

MN ANG RAW SNSR1 (X.X)

Displays the raw value of main angle sensor #1

MN ANG RAW SNSR2 (X.X)

Displays the raw value of main angle sensor #2

RET LEN 1 (X)

displays the retracted length of the tower found by sensor #1 during cali-
bration

RET LEN 2 (X)

displays the retracted length of the tower found by sensor #2 during cali-
bration

EXT LEN 1 (X)

displays the extended length of the tower found by sensor #1 during cali-
bration

EXT LEN 2 (X)

displays the extended length of the tower found by sensor #2 during cali-
bration

TRIP LEN (XXXX.X)

Displays the length of the tower recorded at the transport trip point during
calibration

TA1 CAL L (X.X)

Displays the lowest tower angle #1 value recorded during calibration

TA2 CAL L (X.X)

Displays the lowest tower angle #2 value recorded during calibration

TA1 CAL H (X.X)

Displays the highest tower angle #1 value recorded during calibration

TA2 CAL H (X.X)

Displays the highest tower angle #2 value recorded during calibration

CYL CAL L (X)

Displays the lowest cylinder angle value recorded during calibration

CYL CAL H (X)

Displays the highest cylinder angle value recorded during calibration

Table 6-7. Analyzer Diagnostics Menu

Menu:

Submenu:

Selection:

Description:

Advertising