Figure 4-29. Tower Boom Powertrack Installation - Sheet 1 of 3

0273360-E

Table 4-1. Hose/Cable Pull Chart

Letter

Description

Dim. X

In.

Cm.

A

Platform Supply Hose

60

152

B

Platform Return Hose

7

18

C

Main Tele Extend Hose

7

18

D

Main Tele Retract Hose

7

18

E

Main Lift Extend Hose

60

152

F

Main Lift Retract Hose

60

152

G

Main Lift Pilot Hose

60

152

H

Tower Boom Control Cable

8

20

I

Tower Boom Sensor Harness

8

20

J

AC Cable

62

157

K

Weld Lead

62

157

L

7500W Generator (Optional)

62

157

M

Air Line (Optional)

62

157

NOTE: All X Dimensions are ± 1 in. (2.5 cm)

4.0 ± 0.5 in. (10 ± 1.2 cm)(

MAINTAIN HOSE/CABLE LOOP

AT THIS DIMENSION

6.0 ± 0.5 in. (15.2 ± 1.2 cm)(

MAINTAIN HOSE/CABLE LOOP

AT THIS DIMENSION

4.0 ± 0.5 in. (10 ± 1.2 cm)

5.0 ± 0.5 in. (12.7 ± 2.5 cm)

SEE DETAIL

A

SEE DETAIL

B

DETAIL

A

DETAIL

B