SECTION 4 - BOOM & PLATFORM

4-78

– JLG Lift –

3121171

If the tower boom length sensors are calibrated and
operating properly, the control system will verify the
tower boom length readings are less than 6 in. (15.2
cm). If the tower boom length is not within the limits,
the screen will read:

13. When the machine passes all the configuration

checks, the screen will read:

14. Enter code 55050. The analyzer will read:

WHEN THE STABILITY CONTROL IS OFF THE MACHINE WILL TIP
IF USED INCORRECTLY.

15. Press the ENTER key to acknowledge the stability

control is turned off. The analyzer should read: