SECTION 6 - JLG CONTROL SYSTEM

3121171

– JLG Lift –

6-51

2. Plug the analyzer into the connector inside the

Ground control box.

3. Pull out the Emergency Stop switch and start the

engine.

4. The analyzer screen should read:

5. Use the arrow button to reach ACCESS LEVEL 2. Hit

Enter.

6. Enter the Access Code, 33271.

7. Go to the PERSONALITIES menu.

8. Using the left arrow button, go to the GROUND

MODE menu.

9. Hit ENTER.

10. Using the UP/DOWN arrows, adjust the following

personalities to 100%.

Basket Rotate
Basket Level
Jib U/D (if configured)

Start up the machine and exercise each above plat-
form function (from the ground) eight (8) to ten (10)
times for 5 seconds in each direction.

11. Return the personality settings back to the values as

shown in the Personality Ranges/Defaults table in
Section 6 - JLG Control System.

12. Recycle EMS.

STEP 4: CALIBRATING THE PLATFORM LEVEL
UP AND DOWN VALVE CRACKPOINTS

1. Position the Platform/Ground select switch to the

Ground position.

2. Plug the analyzer into the connector inside the

Ground control box.