Connect control wiring, Overview, N o t e – ETC Unison DRd Dimming Rack Enclosure User Manual

Page 37

Advertising
background image

4

Terminate Wiring

33

Connect Control Wiring

Overview

All low voltage data and option wiring connects to pluggable connectors on the left and right

I/O boards near the bottom of the DRd enclosure.

The DRd ships with a right side I/O board for low voltage control connections. Left side I/O

board is available in the optional Paradigm and Echo Termination Kits.

•

The Paradigm Left I/O Kit supports contact inputs and outputs, serial RS232 and
Ethernet control. This Left I/O board is not compatible with the SmartLink or Echo
Architectural Control Processors.

•

The Echo Network Kit supports an Ethernet connection for the Echo ACP. The Echo
Network Kit is not compatible with the SmartLink or Paradigm ACPs.

•

The right side I/O board is shipped installed with each DRd and provides termination
for SmartLink / LinkConnect / EchoConnect, auxiliary power, DMX, and a UL 924
emergency contact input. The DRd enclosure supports option kits which install in the
bottom of the DRd for extended control and operation and terminate to the right I/O
board. Option modules include:

•

0-10V Control Option (DRd-FLO) which provides 24 outputs for control of 0-10V
(4-wire) control for LED drivers and fluorescent ballasts. Each channel output is
linked one-to-one with a circuit for power control.

•

Digital Addressable Lighting Interface (DRd-DALI) which provides 24 outputs for
control of DALI-compatible fluorescent ballasts. Each channel output of DALI
control is linked one-to-one with a circuit for power control (DALI Broadcast Mode).

•

Unison RideThru kit provides power to the ACP during brief power outages or drop
outs. The URTO sustains power to the ACP for at least 12 seconds.

•

Unison BatteryPack kit sustains power to the ACP for up to 90 minutes during
power outages.

N o t e :

All low voltage control cables must run in separate conduit from power wires.

N o t e :

A DRd enclosure supports the use of either a DALI option board (DRd-DALI) or

the FLO option board (DRd-FLO), but not both.

1
2

3
4

5
6

7
8

9

10

11
12

13
14

15
16

17
18

19
20

21
22

23
24

3

Right I/O board -

ships standard with

each DRd enclosure.

Left I/O board is

available as part of the

Paradigm Termination

Kit which ships with

the Paradigm ACP.

An optional Left I/O kit

is available for use

with Echo ACP when

DRd is being used in a

networked system.

The enclosure door has

been removed from these

graphics for clarity of the

procedure.

Advertising