ETC Unison DRd Dimming Rack Enclosure User Manual

Page 8

Advertising
background image

4

DRd Enclosure Installation Manual

The use of a station power module provides power and control for architectural control
stations.

Use an Echo Station Power Module (E-SPM) to provide power for up to 16 Echo
control stations when used with the Echo ACP.

Use a SmartLink Station Power Module (S-SPM) to provide power for up to 16
SmartLink control stations when used with the SmartLink ACP.

Use a Paradigm Station Power Module (P-SPM) to provide power for up to 32
Paradigm control stations when used with the Paradigm ACP.

The 0-10V control option (DRd-FLO) provides up to 24 outputs for control of 0-10V
(4-wire) LED drivers or fluorescent ballasts (up to 12 on a DRd6).

The Digital Addressable Lighting Interface (DALI) option controls up to 24 loops of 64
DALI compatible ballasts or drivers in a broadcast mode (up to 12 on a DRd6).

The Unison BatteryPack option provides power back-up to the Architectural Control
Processor in the DRd for a period up to 90 minutes.

The Unison RideThru option provides power to the Architectural Control Processor in
the DRd for at least 10 seconds during brief power outages or drop outs.

All empty module spaces in a DRd enclosure must be filled with airflow module or blank
modules (DRd-BM) for proper cooling.

The DRd pedestal (DRd-PED) is a floor mounting stand for the DRd enclosure.