Terminate Wiring

37

Terminate the Unison Options (URTO and UBPO)

Terminate DMX

DMX requires 120

termination at the last DMX

device in the control run. Since a DRd with a

Paradigm module installed can utilize up to two DMX

inputs (2 DMX runs) the right I/O board provides

convenient termination switches for use.

Notice the two termination switches labeled DMXA

and DMXB. Each switch has three termination

positions:

Source - reserved for RDM termination (future
development).

Off - no termination, DMX will pass through this device on to the next DMX device in
the data run.

End - termination is on. Used for the last DMX device (DRd) that is physically
connected in the daisy-chained DMX data run.

When a Paradigm ACP is used in an Unison DRd enclosure, port B will be configured as

an output and cannot be changed. Port A is configured as either a DMX input or output.

When used as an output the DMX termination should always be set to “Off”.

When an Echo or SmartLink ACP is utilized in the Unison DRd enclosure, port A is

automatically configured to be a DMX input and cannot be changed, port B is not used.

N o t e :

A single DRd enclosure supports the use of either the Unison RideThru Option

board or the Unison BatteryPack Option, but not both in one enclosure.

RideThru/Batt

J9

DUAL RACK

LO

Half

Termination is available on the right I/O for the either the Unison

Ride Through Option or the Unison BatteryPack Option. You may

use only one of these option kits per enclosure.

Step 1:

Notice the two pin connector labeled “RideThru / Batt” on

the right I/O board.

Step 2:

Follow the instructions provided in the Setup Guide,

provided with the option kit, for appropriate termination.

APM

-THRU

B

-

COM

A

+

A

-

COM

B

+

B

-

COM

DMXB

DMXA

SRC

OFF

END