1 device connection – HYDAC CSI-F-10 User Manual

Page 25

Advertising
background image

GSM Radio Module CSI-F-10

Page 25

Status 29.01.2009

HYDAC ELECTRONIC GMBH

Part.-Nr.:

669752

6.3.1 Device Connection

• Connect the RS232 serial interface of your PC with the 9-pin SUB-D socket of

the HYDAC interface module CSI-B-2 via a corresponding data cable (or
RS485 via terminal block).

• Connect the CSI-F-10 to the CSI-B-2 via the HSI connection

-X2 / Pin 3 and 4 on the CSI-B-2

Connection B / Pin 4 and 5 on ZBE 26 on the CSI-F-10

• Connect the voltage supply to the CSI-F-10 GSM radio module according to the

diagram.



10,5..35 V D C

H SI

+U

B

G N D

Supply

voltage

RS232

(USB via

appropriate

adaptor)

A

ZBE 26

B

18..35 V DC

+U

B

0V