HYDAC CSI-F-10 User Manual

Page 37

Advertising
background image

GSM Radio Module CSI-F-10

Page 37

Status 29.01.2009

HYDAC ELECTRONIC GMBH

Part.-Nr.:

669752

• In the Interface field, select the option "Open" in order to open the selected

interface (COM port).

The opened interface will be indicated by a green dot on the right-hand edge of
the window.

• In the Sensor field, specify whether you would like to connect to the CSI-F-10

GSM radio module direct, or to one of the sensors connected to it.

• Click on "Change" to open the window for the pass-through mode.

• Select Switch on, to transfer the HMG 510 into the pass-through mode.

Afterwards the following message appears:


• Confirm this with OK.
• "Com Mode" appears in the display of the HMG 510.


Note!
In the pass-through mode a device connected to the PC (in this case: HMG 510)
transfers the data direct to on of the connected sensors or to another device (in this
cae: CSI-F-10) and vice-versa. The PC is then no longer linked to the device directly
connected to it.
In the following example, a HYDACLab

®

with the address "a" is connected to

connection 1 and a CS 1000 is connected to a CS 1000 with the address "b“ (see also
Chapter 6.3.2).

• Afterwards, proceed according to the three options described below.

Advertising