2.3.3 Preconditioning Phases

Because we selected Automatic in the View menu, the graph displays Output
Power
during preconditioning, then switches to Rate during the deposition phase.

As shown in

Figure 2-12

, the initial deposition rate was 10 Å/s until a thickness of

.400 kÅ. Then the deposition rate was ramped up to 15 Å/s, and held until the
desired final thickness of 1.000 kÅ was achieved. At this point, this single-layer
process is finished.

Figure 2-12 Deposition Rate

2.3.4 Deposition Phase with one Rate Ramp

You should adjust the PID parameters on the setting ribbon, then Start/Stop the
process several times to become familiar with their effect on control loop response.

NOTE: In Simulate Mode, a deposition rate is not “measured” until the output

power exceeds 50%.