5 operation – JUMO 705001 mTRON T - Central Processing Unit Operating Manual User Manual
Page 46

5 Operation
46
Generator screen – Start/Stop screen after "Start" button has been pushed
(3)
(1)
(4)
(5)
(6)
(7)
(2)
(8)
(1) Program start
Starts the selected program.
(2) Apply entries without program start (return
to basic status)
(3) Cancel dialog without applying the entries
(return to basic status)
(4) Program selection
All programs that were assigned to the rele-
vant program generator in the program edi-
tor are available for selection here.
(5) Program section that is used for the start of
the program generator
(Only for program start)
(6) Delay of program start
(Not for program start = time or start with
time)
(7) Remaining time in program section
(Only for program start)
If 00:00:00 is set, the program starts when
the relevant program section starts. If
00:10:00 is set (example), the program
starts 10 minutes before the end of the pro-
gram section.
(8) Start time (date and time)
(Only for program start = time or start with