Kinze 3140 Stack Fold Planter Rev. 7/14 User Manual

Page 12

Advertising
background image

M0245-01

Model 3140

1-6

9/12

TM

TRACTOR HYDRAULIC REqUIREMENTS - MECHANICAL

Configuration

Requirements

Description

Base machine with mechanical
meters

1 SCV

10 gpm

#1 SCV: Planter fold

Base machine with mechanical
meters and optional row marker
package

2 SCV

20 gpm

#1 SCV: Planter fold

#2 SCV: Row markers with sequencing/flow control valve

Base machine with mechanical
meters, optional row markers and
dual lift assist package

3 SCV*

20 gpm

#1 SCV: Planter fold
#2 SCV: Row markers with sequencing/flow control valve
#3 SCV: Dual lift assist

Base machine with mechanical
meters, optional row markers,
dual lift assist package, and wing
down flex package

4 SCV*

20 gpm

#1 SCV: Planter fold
#2 SCV: Row markers with sequencing/flow control valve
#3 SCV: Dual lift assist
#4 SCV: wing down flex

*Some options may be combined to reduce the number of SCV outlets required.

TRACTOR HYDRAULIC REqUIREMENTS - EDgEVAC

Configuration

Requirements

Description

Base machine with vacuum
meters (external case drain
required for EdgeVac hydraulic
circuit)

2 SCV

25 gpm

#1 SCV: Vacuum meters

#2 SCV: Planter fold

Base machine with vacuum
meters and optional row marker
package (external case drain
required for EdgeVac hydralulic
circuit)

3 SCV

35 gpm

#1 SCV: Vacuum metering

#2 SCV: Planter fold

#3 SCV: Row markers with sequencing/flow control valve

Base machine with vacuum
meters, optional row marker
package, and dual lift assist
package option (external case
drain required for EdgeVac
hydralulic circuit)

3 SCV*

35 gpm

#1 SCV: Vacuum meters

#2 SCV: Planter fold

#3 SCV: Row markers with sequencing/flow control valve

#4 SCV: Dual lift assist package

#5 SCV: Wing down flex package

*Some options may be combined to reduce the number of SCV outlets required.

Specifications

Advertising