15 kpm iii monitor operation – Kinze 3140 Stack Fold Planter Rev. 7/14 User Manual

Page 95

Advertising
background image

TM

Model 3140

M0245-01

9/12

5-15

KPM III Monitor Operation

When correct distance pulse count is known, calibration is not

needed and the following steps may be used.

STEP 1

Turn knob or use arrow keys to highlight ‘’10. Calibrate

Speed Sensor” and press knob or Enter key

STEP 2

Turn knob or use arrow keys to highlight “3. Change

Distance Pulse Count” and press knob or Enter key.

Highlight “Enter Pulse Count” line and press knob or

Enter key and a drop down key pad will appear.

Status

Plant

About

Setup Mode

Configuration:

Effective row spacing: 15.0

Front / Rear

1. General Settings

2. Seed Meter Settings

3. Row Unit Alarm Levels

4. Setup Data Logging

5. Configure Planter Monitor

6. Add New Muxbus Sensors

7. Add Single Interplant Row

8. Select Speed Sensor

9. Sensor Setup

Logdata

10.Calibrate Speed Sensor

NOTE: Distance Pulse Count will vary from above example.

STEP 3

Turn knob or use arrow keys to highlight the first digit

of the average pulse count and press the knob. The

number will appear in the “Enter Pulse Count” line.

Highlight the next digit of the number and press the

knob. Repeat this procedure until the entire number

is entered then press Enter key.

STEP 4

Turn knob or use arrow keys to highlight “OK” then

press knob or Enter key to return to the “Calibrate

Speed Sensor” screen.

STEP 5

Press F6 key next to “Done” to return to “Setup

Mode” screen.

Done

1. Tractor stopped, Start calibration

2. Tractor stopped, Calibration Done

3. Change Disance Pulse Count

Distance Pulse Count: 185000

English: Drive exactly 330 feet.

Metric: Drive exactly 100 metres.

Calibrate Speed Sensor

Execute step 1 and 2

Effective row spacing: 15.0

Enter Pulse Count

Distance Pulse Count

Cancel

185000

OK

Monitor will display current pulses per mile/kilometer using a 6

digit, no decimal place format labeled “Distance Pulse Count”.

Turn knob or use arrow keys to highlight “Change Pulse Count”

then press knob or Enter key. The “Distance Pulse Count” box

will appear.

When “Enter Pulse Count” value is highlighted press knob

or Enter key and a drop down key pad will appear. Turn

knob or use arrow keys to highlight “0”, zero, and press

knob or Enter key. Turn knob or use arrow keys to highlight

“OK” and press knob or Enter key to return to the “Calibrate

Speed Sensor” screen.

NOTE: If Distance Pulse Count number starts to count pulses

with the tractor not moving, check radar distance sensor for

vibration or other interference.

Done

1. Tractor stopped, Start calibration

2. Tractor stopped, Calibration Done

3. Change Disance Pulse Count

Distance Pulse Count: 185000

English: Drive exactly 330 feet.

Metric: Drive exactly 100 metres.

Calibrate Speed Sensor

Execute step 1 and 2

Effective row spacing: 15.0

Enter Pulse Count

Distance Pulse Count

Cancel

185000

OK

Done

1. Tractor stopped, Start calibration

2. Tractor stopped, Calibration Done

3. Change Disance Pulse Count

Distance Pulse Count: 185000

English: Drive exactly 330 feet.

Metric: Drive exactly 100 metres.

Calibrate Speed Sensor

Execute step 1 and 2

Effective row spacing: 15.0

Enter Pulse Count

Distance Pulse Count

Cancel

0

2

0

1 2 3

C

4 5 6
7 8 9

.

0

-

OK

Advertising