Field check granular chemical application, Field check granular chemical application -24 – Kinze 3140 Stack Fold Planter Rev. 7/14 User Manual

Page 38

Advertising
background image

M0245-01

Model 3140

2-24

9/12

TM

Machine Operation

1.

Fill insecticide and/or herbicide hoppers.

2.

Attach a calibrated vial to each granular chemical meter.

NOTE: Disengage clutch to avoid dropping seed during test.

3.

Lower planter and drive 1320 feet at planting speed.

4.

Weigh chemical in ounces caught in one vial.

5.

Multiply that amount by factor shown to determine pounds per acre.

EXAMPLE: You are planting 30" rows. You have planted for 1320 feet at desired planting speed. You caught 12.0
ounces of chemical in one vial. 12.0 ounces times 0.83 equals 9.96 pounds per acre.

NOTE: Check calibration of all rows.

METERING GATE

Use metering gate setting as a starting point for distributing insecticide or herbicide. Charts are based on 5 mph
(8 kph) planting speed. Use a higher gate setting for speeds faster than 5 mph (8 kph) and a lower setting for speeds
slower than 5 mph (8 kph).

FIELD CHECK gRANULAR CHEMICAL APPLICATION

Temperature, humidity, speed, ground conditions, flowability of different material, or meter obstructions can affect
granular chemical rate of delivery.

wARNINg

Agricultural chemicals can cause death or serious injury to persons,
animals, and plants or seriously damage soil, equipment, or property.
Read and follow all chemical and equipment manufacturers labels
and instructions.

Perform a field check to determine application rates.

granular chemical field check

Pounds Per Acre

Row width

Factor

30"

.83

36"

.69

38"

.65

Calibrated vial

Advertising