4technical data – Lenze E94AYCIB User Manual

Page 19

Advertising
background image

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17

19

4

Technical data

4.4

Protective insulation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Example
Which type of protective insulation is used between the bus terminal of the device module in slot

MXI1 or MXI2 and the mains terminal X100?
The separate potential area with the better protective insulation is decisive.

• The separate potential area of the bus terminal of the device module has a "functional

insulation".

• The separate potential area of the mains terminal has a "reinforced insulation".

Result: The insulation between mains terminal X100 and the bus terminal is of the "reinforced

insulation" type.

Terminal strip Connection

Terminal strip Connection

X100 L1, L2, L3 (Single Drive only)

X1 CAN on board 9400

+UG, -UG

X2 State bus

X105 U, V, W

24 V (ext.)

Rb1, Rb2 (Single Drive only)

X3 Analog inputs/outputs

X106 Motor PTC

X4 Digital outputs

X107 Control of the motor holding

brake

X5 Digital inputs
X6 Diagnostics
X7 Resolver
X8 Encoder

MXI1, MXI2 Extension module

MMI Memory module

MSI Safety module

X205 External voltage supply (24 V DC)
X206 INTERBUS connection, input (IN)
X207 INTERBUS connection, output

(OUT)