13

Parameter reference

13.2

Parameters of the communication module for slot MXI1

62

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13901

C13902

C13920

Parameter | Name:

C13901 | Firmware compilation date

Data type: VISIBLE_STRING

Index: 10674 = 0x29B2

Display of the compilation date of the firmware (string with a length of 20 bytes)

• The date ("MMM TT JJJJ") and the time ("hh:mm:ss") are output, e.g. "Mar 21 2005 12:31:21".

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13902 | Firmware version

Data type: VISIBLE_STRING

Index: 10673 = 0x29B1

Display of the firmware version (string with a length of 8 bytes)

The identification code is output, e.g. "01.00.00".

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13920 | Display of DIP switch position

Data type: BITFIELD_8

Index: 10655 = 0x299F

Display of the current DIP switch position

• The set parameter data length (PCP) is displayed in

C13860/1

.

• The set process data length is displayed in

C13860/2

.

• The set baud rate is displayed in

C13863

.

Possible settings via DIP switch ( 30)

Value is bit-coded:

Info

Bit 0 DIP 8

Baud rate

Bit 1 DIP 7

No response

Bit 2 DIP 6

Number of parameter data words (PCP)

Bit 3 DIP 5
Bit 4 DIP 4

Number of process data words

Bit 5 DIP 3
Bit 6 DIP 2
Bit 7 DIP 1

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT