Electrical installation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2.3
INTERBUS connection
The INTERBUS of the communication module is connected via the 9-pole Sub-D plug X206 (input)
and the 9-pole Sub-D socket X207 (output).
[5-5]
INTERBUS terminals X206 (input) and X207 (output)
Assignment of the 9-pole Sub-D plug X206 (IN)
E94YCIB001C
Pin
Name
Input/output
Description
1
DO1
Input
RS485: DO1 not inverted
2
DI1
Output
RS485: DI1 not inverted
3
GND
Reference potential
4
Free
not assigned
5
Vcc5
Output
5 V DC
6
/DO1
Input
RS485: DO1 inverted
7
/DI1
Output
RS485: DI1 inverted
8
Vcc5
Output
5 V DC
9
Free