Installation

5.2

Electrical installation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.3

INTERBUS connection

The INTERBUS of the communication module is connected via the 9-pole Sub-D plug X206 (input)

and the 9-pole Sub-D socket X207 (output).

[5-5]

INTERBUS terminals X206 (input) and X207 (output)

Assignment of the 9-pole Sub-D plug X206 (IN)

E94YCIB001C

Pin

Name

Input/output

Description

1

DO1

Input

RS485: DO1 not inverted

2

DI1

Output

RS485: DI1 not inverted

3

GND

Reference potential

4

Free

not assigned

5

Vcc5

Output

5 V DC

6

/DO1

Input

RS485: DO1 inverted

7

/DI1

Output

RS485: DI1 inverted

8

Vcc5

Output

5 V DC

9

Free

not assigned