C13852 | all words to the basic device, C13853 | all words to the basic device, C13854 | length of ports mapped into receive pdo – Lenze E94AYCIB User Manual

Page 57: C13854/1, 13 parameter reference

Advertising
background image

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17

57

13

Parameter reference

13.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13852

C13853

C13854

Parameter | Name:

C13852 | All words to the basic device

Data type: UNSIGNED_16

Index: 10723 = 0x29E3

Display of the process data words which are transmitted from the communication module to the standard device.

• In the subcodes 1 ... 32, all process data words from the communication module are displayed.

Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13852/1
...
C13852/32

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13853 | All words to the basic device

Data type: UNSIGNED_16

Index: 10722 = 0x29E2

Display of the process data words which are transmitted from the standard device to the communication module.

• In the subcodes 1 ... 32, all process data words from the standard device are displayed.

Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13853/1
...
C13853/32

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13854 | Length of ports mapped into receive PDO

Data type: UNSIGNED_8

Index: 10721 = 0x29E1

Display of the total data length (in bytes) of the ports that have been entered into the receive PDO.

The data word sum (process data words + parameter data words) has to consist of 1 ... 10 words (16 bits/word).

Configuring process data (PDO mapping) ( 37)

Display area

(min. value | unit | max. value)

0

64

Subcodes

Info

C13854/1

Length of the ports entered into the receive PDO

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising