Parameter data transfer

9.2

Initialising PCP communication

40

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.2

Initialising PCP communication

Make entries into the CRL (communication relation list) in order that communication between the

INTERBUS master and the communication module can take place.
Make the following entries in the CRL of the INTERBUS master:

Field name

Entry

Communication reference

2

Connection type

Master slave acyclic

Connection attribute

Defined

Max-PDU Sending-High-Prio

0

Max-PDU Sending-Low-Prio

64

Max-PDU Receiving-High-Prio

0

Max-PDU Receiving-Low-Prio

64

Supported Services Request

0x803000

Supported Services Response

0x000000

Maximum SCC

1

Maximum RCC

1

Maximum SAC

1

Maximum RAC

1