9.3

Supported PMS services

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.3

Supported PMS services

The parameter data is transferred via PMS services.
In the following, only parameters and their contents are given that are returned by the Lenze

inverters. All other transfer parameters of the given PMS services can be obtained from the

corresponding descriptions of the INTERBUS master.
The following PMS services are supported by Lenze inverters:

• Initiate: Establish a connection of the INTERBUS master to the inverter
• Abort: Abort connection
• Reject: Reject impermissible PMS service
• Read: Read parameters
• Write: Write parameters
• Get-OD: Read out the object directory
• Identify: Identification of the inverter
• Status: Read the status of the inverter

9.3.1

Initiate

The "Initiate" PMS service establishes a logic connection between the INTERBUS master and the

communication module.
The inverter provides the following parameters:

9.3.2

Abort

The "Abort" PMS service aborts a logic connection between the INTERBUS master and the

communication module.

9.3.3

Reject

The "Reject" PMS service rejects a non-supported PMS service.

Name

Value

Description

Profile number

0

No profile is supported.

Password

0

The password function of INTERBUS is not supported.

Access groups

0

No access groups exist.

Access-Protection Supported

TRUE

Access protection is supported.

Version OD

0

Version of the object directory