9 parameter data transfer, 1 addressing of the parameter data, Parameter data transfer – Lenze E94AYCIB User Manual

Page 39: Addressing of the parameter data, 9parameter data transfer

Advertising
background image

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17

39

9

Parameter data transfer

9.1

Addressing of the parameter data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9

Parameter data transfer

The parameter data of Lenze devices are contained in codes which are listed in this documentation

and the documentation of the Servo Drive 9400.

Parameter reference

( 53)

9.1

Addressing of the parameter data

The parameters of a Lenze device are not directly addressed via codes but via an index and subindex.
The conversion is made via an offset: 24575 or 0x5FFF

• INTERBUS index (decimal) = 24575 - Lenze code number (decimal)
• INTERBUS index (hexadecimal) = 0x5FFF - Lenze code number (hexadecimal)

Example of C00105 (deceleration time quick stop (QSP)):

• INTERBUS index (decimal) = 24575 - 105 = 24470
• INTERBUS index (hexadecimal) = 0x5FFF - 0x69 = 0x5F96

Parameter changes must be saved via code C00002 of the Servo Drive 9400.