2 wiring of the interbus, Wiring of the interbus, Wiring of the interbus ( 24) – Lenze E94AYCIB User Manual

Page 24: 5installation

Advertising
background image

5

Installation

5.2

Electrical installation

24

Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.2

Wiring of the INTERBUS

For communication with the master and all further components, Servo Drives 9400 have to be

assembled with communication modules.
The INTERBUS system has to be designed as a ring. Here, go and return lines are integrated in the

same bus cable. The ring comes from the INTERBUS master via all other nodes back again to the

master.
An INTERBUS ring can consist of maximally 513 nodes (1 master + further slaves (slaves)).

[5-4]

INTERBUS ring

E94YCIB008

M: Master (e.g. PLC, Industrial PC)

S1 ... Sn: Slaves

500 kBit/s:

400 m

2 MBit/s:

£

150 m

£

Servo Drive

9400

E94AYCIB

X206

X207

Servo Drive

9400

E94AYCIB

X206

X207

Servo Drive

9400

E94AYCIB

X206

X207

OUT

IN

OUT

IN

IN

M

S2

S1

Sn

Advertising