C13855

C13860

C13861

Parameter | Name:

C13855 | Length of ports mapped into send PDO

Data type: UNSIGNED_8

Index: 10720 = 0x29E0

Display of the total data length (in bytes) of the ports that have been entered into the send PDO.

The data word sum (process data words + parameter data words) has to consist of 1 ... 10 words (16 bits/word).

Configuring process data (PDO mapping) ( 37)

Display area

(min. value | unit | max. value)

0

64

Subcodes

Info

C13855/1

Length of the ports entered into the send PDO

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13860 | Settings

Data type: UNSIGNED_8

Index: 10715 = 0x29DB

Display of the set number of the

• Parameter data words

• Process data words

The data word sum (process data words + parameter data words) has to consist of 1 ... 10 words (16 bits/word).
Display area

(min. value | unit | max. value)

0

10

Subcodes

Info

C13860/1

Display of parameter data length (PCP)

C13860/2

Display of process data length

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13861 | Bus status

Data type: BITFIELD_16

Index: 10714 = 0x29DA

Display of the current bus status

Meaning of the resulting hexadecimal values:

• 0xyyy0 = IBS-INIT

• 0xyyy1 = IBS-ACTIVE

• 0xyyy2 = IBS-READY

Querying the current bus status ( 48)

Value is bit-coded:

Info

Bit 0 Bit 0

... ...

Bit 15 Bit 15

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT