EDS84DMOTPBUS EN 3.0 - 11/2011

L

17

Communication manual 8400 motec PROFIBUS

Product description

Connections and interfaces

 On delivery, the PROFIBUS connections and the LEDs for the PROFIBUS status displays

are already mounted and wired:
– PROFIBUS input to plug connector X31
– PROFIBUS output to plug connector X32
– LEDs to plug connector X55

 It is also possible to connect the PROFIBUS and other inputs and outputs (e.g. digital

inputs) via the positions A1 ... A4 and B1 ... B4.

 For the connections, 5-pin M12 connectors or - alternatively - cable glands (cable cross-

section max. 1.0 mm

2

, AWG 18) can be used.

 The M12 connectors, cable glands and prefabricated system cables can be obtained

from diverse manufacturers.

 Wire the M12 connectors or cable glands used to the corresponding contacts of the

terminal strips/plug connectors X3, X4 and X61.

Hardware manual "Inverter Drives 8400 motec"
Observe the notes and wiring instructions given in the documentation.