C13887 | suppress signalling diag. mess, C13899 | station address, C13900 | firmware product type – Lenze E84DGFCP User Manual

Page 87: C13901 | firmware compilation date, C13902 | firmware version, C13887, C13899, The dip switches, Communication manual 8400 motec profibus

Advertising
background image

EDS84DMOTPBUS EN 3.0 - 11/2011

L

87

Communication manual 8400 motec PROFIBUS

Parameter reference

Parameters relevant for PROFIBUS communication

C13887

C13899

C13900

C13901

C13902

Parameter | Name:

C13887 | Suppress signalling diag. mess.

Data type: BITFIELD_8

Index: 10688

d

= 29C0

h

From version 02.00

Bit coded selection of the error responses in the drive unit, at which diagnostic signalling is suppressed.
Value is bit-coded:

Info

Bit 0 Error
Bit 1 Trouble
Bit 2 Reserved
Bit 3 Warning locked
Bit 4 Reserved

... ...

Bit 7 Reserved

;

Read access ; Write acces … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13899 | Station address

Data type: UNSIGNED_8

Index: 10676

d

= 29B4

h

Optional setting of the station address (instead of setting via DIP switches 1 ... 64)

• The station address set here only becomes effective if the DIP switch S has been set to ON and the DIP switches

1 ... 64 have been set to OFF prior to power-on.

• The active station address is displayed under

C13864

.

• The changed station address will only be effective after the parameter set has been saved followed by a

subsequent mains switching of the communication unit or controller.



Setting the station address ( 31)

Setting range

(min. value | unit | max. value)

Lenze setting

3

126 3

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C13900 | Firmware product type

Data type: VISIBLE_STRING

Index: 10675

d

= 29B3

h

Display of the product type (string with a length of 8 bytes)

• The following identification code is displayed: "E84DGFCP".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13901 | Firmware compilation date

Data type: VISIBLE_STRING

Index: 10674

d

= 29B2

h

Display of the compilation date of the firmware (string with a length of 20 bytes)

• The date ("MMM DD YYYY") and time ("hh:mm:ss") are displayed, e.g. "Mar 21 2005 12:31:21".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13902 | Firmware version

Data type: VISIBLE_STRING

Index: 10673

d

= 29B1

h

Display of the firmware version (string with a length of 5 bytes)

• An identification code is displayed, e.g. "00.80".

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT