EDS84DMOTPBUS EN 3.0 - 11/2011

L

25

Communication manual 8400 motec PROFIBUS

Installation

Electrical installation

5.2.3

Bus cable specification

Bus cable length
The bus cable length depends on the baud rate used:

Tip!
For high baud rates, we recommend taking the use of optical fibres into

consideration.
Advantages of optical fibres:
• External electromagnetic interferences have no effect on the transmission

path.

• Bus lengths of several kilometres are also possible with higher baud rates.

The bus length is ...
– independent of the baud rate;
– dependent on the optical fibre used.

Note!

Only use cables that correspond to the given specifications of the PROFIBUS user

organisation.

Area

Values

Cable resistance

135 ... 165 Ω/km, (f = 3 ... 20 MHz)

Capacitance per unit length

30 nF/km

Loop resistance

< 110 Ω/km

Core diameter

> 0.64 mm

Core cross-section

> 0.34 mm

2

Cores

Twisted in pairs, insulated and shielded

Baud rate

Length

9.6 ... 93.75 kbps

1200 m

187.5 kbps

1000 m

500 kbps

400 m

1500 kbps

200 m

3000 ... 12000 kbps

100 m

Note!

The baud rate depending of the data volume, cycle time and number of stations

should only be selected as high as required for the application.