3 profidrive parameter data channel (dp-v1), Profidrive parameter data channel (dp-v1), Communication manual 8400 motec profibus – Lenze E84DGFCP User Manual

Page 51

Advertising
background image

EDS84DMOTPBUS EN 3.0 - 11/2011

L

51

Communication manual 8400 motec PROFIBUS

Parameter data transfer

PROFIdrive parameter data channel (DP-V1)

9.3

PROFIdrive parameter data channel (DP-V1)

Data communication with PROFIBUS DP-V0 is characterised by cyclic diagnostics and cyclic

process data and parameter data transfer.
An optional service extension is the acyclic parameter data transfer of PROFIBUS DP-V1 (in

preparation). This service does not impair the functionality of the standard services under

PROFIBUS DP-V0.
PROFIBUS DP-V0 and PROFIBUS DP-V1 can be operated simultaneously in the same

network. This enables the step-by-step expansion or modification of a system.
The services of PROFIBUS DP-V1 can be used by the class 1 master (PLC) and the class 2

master (diagnostics master, etc.).
The integration of the acyclic service into the fixed bus cycle depends on the corresponding

configuration of the class 1 master:

 With configuration, a time slot is reserved.
 Without configuration the acyclic service is appended when a class 2 master acyclically

accesses a DP-V1 slave.

Features

 Parameter number and subindex addresses with a width of 16 bits each.
 Several parameter requests can be combined to one request (multi-parameter

request).

 There is always only one parameter request in process (no pipelining).
 A parameter request/response must fit into a data block (max. 240 bytes). Requests/

responses cannot be split into several data blocks.

 No spontaneous messages are transferred.
 There are only acyclic parameter requests.
 Profile-specific parameters can be read independently of the slave state.