Commissioning

Possible settings via DIP switch

30

L

EDS84DMOTPBUS EN 3.0 - 11/2011

6.3

Possible settings via DIP switch

[6-1]

DIP switch

6.3.1

Receiving the station address via the master

Set the DIP switch S = OFF, in order to receive the station address automatically via the

master.

 The station address active at the PROFIBUS is displayed in

C13864

.

 The settings of the DIP switches 1 ... 64 have no effect.

The DIP switches serve to ...

Setting the station address

( 31)

(switches: 1 ... 64)

Receiving the station address via the master

( 30)

(switch: S)

Lenze setting: all switches in OFF position

Note!

• The DIP switches can only be accessed when the drive unit is detached from

the communication unit. Loosen the four fixing screws at the drive unit.

Observe the notes in the mounting instructions.

• Switch off the voltage supply of the controller and the external supply of the

communication unit before starting with the disassembly of the drive unit.

• The DIP switches are only read in when the device is switched on.