C13866 | display: most recent cfg data, C13867 | display: most recent diagnostic data, C13880 | reaction on communication failure – Lenze E84DGFCP User Manual

Page 85: C13881 | monitoring time: data exchange, C13880/1, Set for the "data_exchange" state, C13881, Slave in, Lenze setting, Triggers the response parameterised under

Advertising
background image

EDS84DMOTPBUS EN 3.0 - 11/2011

L

85

Communication manual 8400 motec PROFIBUS

Parameter reference

Parameters relevant for PROFIBUS communication

C13866

C13867

C13880

C13881

Parameter | Name:

C13866 | Display: Most recent CFG data

Data type: OCTET_STRING

Index: 10709

d

= 29D5

h

Display of the last configuration data sent by the PROFIBUS master with the "Chk-Cfg" telegram (ASCII string with

22 characters)

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13867 | Display: Most recent diagnostic data

Data type: OCTET_STRING

Index: 10708

d

= 29D4

h

Display of the last diagnostic data sent to the PROFIBUS master (ASCII string with 16 characters)

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13880 | Reaction on communication failure

Data type: UNSIGNED_8

Index: 10695

d

= 29C7

h

Monitoring response to a communication fault on the PROFIBUS

• A change in the monitoring response is effective immediately.



Permanent interruption of PROFIBUS communication ( 69)

Selection list

0 No response
1 Error
4 Warning locked

Subcodes

Lenze setting

Info

C13880/1

0: No response

The response set here for the "watchdog/data exchange"

monitoring is executed if the bus station ...

• does not receive a message from the master within

the watchdog monitoring time (during an active

connection displayed under

C13882/1

).

• detects that it is no longer in the "Data_Exchange"

state. Please see also the notes given under

C13881

.

;

Read access ; Write acces … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13881 | Monitoring time: Data exchange

Data type: UNSIGNED_16

Index: 10694

d

= 29C6

h

If the "Data_Exchange" state has been exited, the response parameterised with

C13880/1

is carried out when the

monitoring time set here for the data exchange has expired.

• A value of "65535" in this code deactivates the monitoring function.

• A change in monitoring is effective immediately.

• The value set here for the monitoring time must be smaller than the watchdog monitoring time (displayed under

C13882/1

).



Permanent interruption of PROFIBUS communication ( 69)

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 65535 ms

;

Read access ; Write acces … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT