2 drivecom parameters, Drivecom parameters, Parameter setting – Lenze 2131IB User Manual

Page 25

Advertising
background image

Parameter setting

6-2

BA2131EN

Lenze data types

The possible Lenze parameters and their value ranges can be obtained from the corresponding
Operating Instructions for the controller.
The data of the Lenze parameters are mainly represented in a fixed-point format of the data type
Integer32 with four decimal digits. This means, that the parameter value listed in the Operating
Instructions must be multiplied with 1000.

Example:
Operating Instructions L-C0039 (JOG) = 150.4 Hz
results in 150.4 x 10000 = 1504000

dec

(0016F300

hex

)

82Xx parameter sets

The 82XX controller is equipped with 2 parameter sets, which can be directly addressed via the
PROFIBUS. They are addressed by means of a code-digit offset:

l

Offset 0 addresses parameter set 1 with the Lenze codes L-C0000 to L-C1999

l

Offset 2000 addresses parameter set 2 with the Lenze codes L-C2000 to L-C3999

If a parameter is only available once (see 82XX Operating Instructions), use the code offset 0.

Example for L-C0011 (maximum field frequency):
L-C0011 in parameter set 1: Lenze code = 11
L-C0011 in parameter set 2: Lenze code = 2011

Changes of the parameters are automatically saved in the controller (see Operating Instructions
82XX). Exceptions are the process data, e.g. control words or setpoints.

Parameter sets for 8200 vector

The 8200 vector controller is equipped with 4 parameter sets, which can be directly addressed via
the PROFIBUS. They are addressed by means of a code-digit offset:

l

Offset 0 addresses parameter set 1 with the Lenze codes L-C0000 to L-C1999

l

Offset 2000 addresses parameter set 2 with the Lenze codes L-C2000 to L-C3999

l

Offset 4000 addresses parameter set 3 with the Lenze codes L-C3000 to L-C4999

l

Offset 6000 addresses parameter set 4 with the Lenze codes L-C6000 to L-C7999

If a parameter is only available once (see Operating Instructions 8200 vector), use the code offset
0.

Example for L-C0011 (maximum field frequency):
L-C0011 in parameter set 1: Lenze code = 11
L-C0011 in parameter set 2: Lenze code = 2011
L-C0011 in parameter set 3: Lenze code = 4011
L-C0011 in parameter set 4: Lenze code = 6011

Changes of the parameters are automatically saved in the controller (see Operating Instructions
8200 vector). Exceptions are the process data, e.g. control words or setpoints.

Parameter sets for 93XX

The 93XX controllers are equipped with 4 parameter sets for non-volatile storage. Another
parameter set is in the user memory of the controller. This is the current parameter set. Only the
current parameter set can be directly addressed via PROFIBUS. For the codes, see Operating
Instructions or Manual for 93XX. Changes of the current parameter set will be lost after switching
off the controller. Code C0003 is for saving the current parameter set. After switching on the
controller, parameter set 1 is automatically loaded into the current parameter set.

6.1.2

DRIVECOM parameters

In the following, the controller parameters, which are standardized according to the DRIVECOM
profile 20, are named DRIVECOM parameters. Each DRIVECOM parameter is addressed by means
of the index.

Show/Hide Bookmarks

Advertising