Parameter setting, Show/hide bookmarks, Ba2131en – Lenze 2131IB User Manual

Page 38

Advertising
background image

Parameter setting

6-15

BA2131EN

Inhibit voltage
xxxx xxxx xxxx xx0x

automatically when
fault reaction is over

Standstill
xxxx xxxx
xxxx x110

Standstill
xxxx xxxx xxxx
x110

Switch on
xxxx xxxx
xxxx x111

automatically when in-

itializing is completed

Reset fault
xxxx xxxx 0xxx xxxx

Switch on unit

Status word xxxx xxxx x0xx 0000

NOT READY TO SWITCH ON

READY TO SWITCH ON

Status word xxxx xxxx x01x 0001

SWITCHED ON

Status word xxxx xxxx x01x 0011

OPERATION ENABLED

Status word xxxx xxxx x01x 0111

Fault

Status word xxxx xxxx x0xx 1000

Example:
Status information by means of “status word“
Bit 15 ... bit 0 (binary display)

SWITCH ON INHIBIT

Status word xxxx xxxx x0xx 0000

QUICK STOP ACTIVE

Status word xxxx xxxx x01x 0111

Operation enable
xxxx xxxx xxxx 1111 and
act. speed value <> 0*

Operation inhibit
xxxx xxxx xxxx 0111 or act.
speed value = 0*

Inhibit RFG is mapped to quick
stop

Quick stop

xxxx xxxx xxxx x01x

Quick stop
xxxx xxxx xxxx x01x

Inhibit voltage
xxxx xxxx xxxx xx0x

Standstill
xxxx xxxx xxxx x110

MALFUNCTION REACTION ACTIVE

Status word xxxx xxxx x0xx 1111

Fault
was
recognized

xxxx xxxx 1xxx xxxx

Inhibit voltage
xxxx xxxx xxxx xx01
or
quick stop completed

9

8

4

5

11

6

7

10

12

14

13

3

Note:

* only effective for 821X, 8200 vector when the

automatic DC-injection brake is active (L-C0106,

L-C2106 <> 0)

2

Fig. 6-4

Status diagram DRIVECOM unit control

Status

Meaning

NOT READY TO SWITCH
ON

The controller is being initialized and is not yet ready to operate. It automatically switches to the status READY TO SWITCH ON.

SWITCH-ON INHIBIT

The controller is inhibited and waits for command 2 (shut down).

READY TO SWITCH ON

The controller is inhibited and waits for command 3 (switch on).

SWITCHED ON

The controller is inhibited and waits for command 4 (enable operation).

OPERATION ENABLED

The controller is enabled. In this status, a pulse inhibit can be set automatically.

FAULT REACTION ACTIVE

A fault (TRIP) was recognized and a fault response initiated.

FAULT

The controller is in the status “FAULT“ (TRIP).

QUICK STOP ACTIVE

While being in the status “OPERATION ENABLED“ the command “quick stop“ was set. The controller is decelerated in a controlled way
(quick-stop ramp). After deceleration, the controller automatically changes to the controller status “SWITCH ON INHIBIT“.