3 technical data, 1 features of the 2131 fieldbus module, 2 general data / application conditions – Lenze 2131IB User Manual

Page 9: Features of the 2131 fieldbus module, General data / application conditions, Technical data, 3technical data

Advertising
background image

Technical data

3-1

BA2131EN

3

Technical data

3.1

Features of the 2131 fieldbus module

The 2131 fieldbus module has the following features:

l

Attachable additional module for Lenze controller series 820X, 821X, 8200 vector, 822X and
93XX

l

Slave interface module for the communication system PROFIBUS with the communication
profile PROFIBUS-DP (DIN19245 part 1 and part 3)

l

Automatic baud rate detection

l

Baud rate between 9.6 kbaud and 12 Mbaud

l

Optionally 4 or 6 byte proces data

l

Optional parameter-setting channel

l

Access to all Lenze parameters

l

Application profile: DRIVECOM Profil 20

3.2

General data / application conditions

Field

Values

Order designation

33.2131IB

Communcation medium

RS485

Network topology

Line

Max. cable length

1200 m (depending on the desired baud rate and the cable type used)

PROFIBUS participants

Slave

Communication profile

PROFIBUS-DP (DIN 19245 part 1 and part 3)

Drive profile

DRIVECOM profile 20

Baud rate

9.6 kbit/s to 12000 kbit/s

Ambient temperature

during operation:

0

to

50

˜C

Transport:

-25

to

70

˜C

Storage:

-25

to

55

˜C

Permissible humidity

Class 3K3 to EN 50178 (without condensation, average relative humidity 85%)

24-V-DC-
Voltage supply

l

820X / 8200 vector (observe chapter 4.3.1):

only external supply

l

821X / 822X / 8200 vector (observe chapter 4.3.1) / 93XX:

internal or external supply