Parameter setting
6-19
BA2131EN
The following table shows the assignment of the DRIVECOM control word 93XX depending on the
selected signal configuration L-C0005:
Signal
configuration
L-C0005
Bit 5
(AIF-CTRL.B4)
Bit 6
(AIF-CTRL.B5)
Bit 11
(AIF-CTRL.B7)
Bit 12
(AIF-CTRL.B12)
Bit 13
(AIF-CTRL.B13)
Bit 14
(AIF-CTRL.B14)
Bit 15
(AIF-CTRL.B15)
Speed control
1003
1013
1113
NSET-RFG-STOP
(RFG stop)
NSET-CTRL.
ENABLE-0 (RFG
zero)
Not assigned
DCTRL-PAR*1
DCTRL-PAR-LOAD
NSET-
TI*1
NSET-
TI*2
Torque control
4003
4013
4113
NSET-RFG-STOP
(RFG stop)
NSET-CTRL.
ENABLE-0 (RFG
zero)
Not assigned
DCTRL-PAR*1
DCTRL-PAR-LOAD
NSET-JOG*1
NSET-JOG*2
DF master
5003
5013
5113
NSET-RFG-STOP
(RFG stop)
NSET-CTRL.
ENABLE-0 (RFG
zero)
Not assigned
DCTRL-PAR*1
DCTRL-PAR-LOAD
REF-ON
NSET-TI*1
DF-slave bus
6003
6013
6113
Not assigned
Not assigned
Not assigned
DCTRL-PAR*1
DCTRL-PAR-LOAD
REF-ON
Not assigned
DF-slave cascade
7003
7013
7113
Not assigned
Not assigned
Not assigned
DCTRL-PAR*1
DCTRL-PAR-LOAD
REF-ON
Not assigned