Parameter setting – Lenze 2131IB User Manual

Page 42

Advertising
background image

Parameter setting

6-19

BA2131EN

The following table shows the assignment of the DRIVECOM control word 93XX depending on the
selected signal configuration L-C0005:

Signal
configuration
L-C0005

Bit 5
(AIF-CTRL.B4)

Bit 6
(AIF-CTRL.B5)

Bit 11
(AIF-CTRL.B7)

Bit 12
(AIF-CTRL.B12)

Bit 13
(AIF-CTRL.B13)

Bit 14
(AIF-CTRL.B14)

Bit 15
(AIF-CTRL.B15)

Speed control
1003
1013
1113

NSET-RFG-STOP
(RFG stop)

NSET-CTRL.
ENABLE-0 (RFG
zero)

Not assigned

DCTRL-PAR*1

DCTRL-PAR-LOAD

NSET-
TI*1

NSET-
TI*2

Torque control
4003
4013
4113

NSET-RFG-STOP
(RFG stop)

NSET-CTRL.
ENABLE-0 (RFG
zero)

Not assigned

DCTRL-PAR*1

DCTRL-PAR-LOAD

NSET-JOG*1

NSET-JOG*2

DF master
5003
5013
5113

NSET-RFG-STOP
(RFG stop)

NSET-CTRL.
ENABLE-0 (RFG
zero)

Not assigned

DCTRL-PAR*1

DCTRL-PAR-LOAD

REF-ON

NSET-TI*1

DF-slave bus
6003
6013
6113

Not assigned

Not assigned

Not assigned

DCTRL-PAR*1

DCTRL-PAR-LOAD

REF-ON

Not assigned

DF-slave cascade
7003
7013
7113

Not assigned

Not assigned

Not assigned

DCTRL-PAR*1

DCTRL-PAR-LOAD

REF-ON

Not assigned