Parameter setting

6-11

BA2131EN

6.4.3

Process-data assignment for 93XX

Unlike the 82XX controller, the process-data assignment of the 93XX controller can be changed via
reconfiguration of the function blocks AIF-IN and AIF-OUT.

Structure of the PO data response

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

DRIVECOM
Control word
High byte

DRIVECOM
Control word
Low byte

AIF-IN.W1
High byte

AIF-IN.W1
Low byte

AIF-IN.W2
High byte

AIF-IN.W2
Low byte

AIF-IN.W1 to AIF-IN.W2 depend on the signal configuration selected under L-C0005 and are then
sensibly preassigned.

Signal configuration (L-C0005)

AIF-IN.W1

AIF-IN.W2

Speed control
1003
1013
1113

NSET-N
Speed setpoint

Not assigned

Torque control
4003
4013
4113

MCTRL-MADD
Torque setpoint

Not assigned

DF master
5003
5013
5113

NSET-N
Speed setpoint

Not assigned

DF-slave bus
6003
6013
6113

DFSET-A-TRIM
Phase trimming

DFSET-N-TRIM
Speed trimming

DF-slave cascade
7003
7013
7113

DFSET-VP-DIV
DF factor

DFSET-A-TRIM
Phase trimming

Not equal to xxx3 (except own
configurations)

Not assigned

Not assigned

For detailed description of the 93XX signal configuration see the Operating Instructions for 93XX
(only the main configurations: 1000, 4000, 5000, etc.) or the Manual 93XX.

In the controller other signals can be assigned to AIF-IN.W1 to AIF-IN.W2. For this, the
function-block configuration - described in the Manual 93XX - is used. The function block AIF-IN
determines the input data of the controller as data interface for the 2131IB fieldbus module.

For more detailed information about the function block AIF-IN, see the Manual 93XX.