Parameter setting

6-4

BA2131EN

The following table shows the assignment of the addresses:

PROFIBUS-DP station address

Mapping to code C0009 LECOM unit address

1-2

No (master addresses)

3-99

Yes (3-99)

100-125

Yes (C0009= 2)

126 (Lenze setting )

Yes (C0009= 1 )

6.1.5

Baud rate

Baud-rate settings are not required. The 2131 fieldbus module is automatically adjusted to the baud
rate of the master.

6.1.6

Master settings

The master needs a unit-description file (unit master-data file) for operation with PROFIBUS-DP. The
diskette provides the following files:

File name

Meaning

L_AR00AA.GSD

Unit master-data file to DIN 19245 T3

LE00AATD.200

Controller master data file (type file) for Simatic-S5 COM-ET200 V4.X (IM308B)

LE00AAAX.200

Controller master data file (type data) for Simatic-S5 COM-ET200 V5.X (IM308C)

You also have to set:

Function

Setting (depends on the master type)

Baud rate

The 2131 module is equipped with an automatic baud-rate detection

Communication profile

PROFIBUS-DP DIN E 19245 T3

Slave-station address

126 (Lenze setting)
Value the same as in controller parameter C0009 (see chapter 6.1.4 “Bus
address/station address“).

DP-configuration data (configuration)

see chapter 6.2

PNO-identification number

00AA

hex

DP user-data length

see chapter 6.2

6.2

PROFIBUS-DP configuration

The PROFIBUS-DP user data length is determined during the DP initialization phase (configuration).
You can select from 4 fixed lengths.

The user data lengths for input data and output data must be the same.

For simplification we use the following abbreviations:

l

PIW:
Process input word (process data from the controller to the master)

l

POW:
Process output word (process data from the master to the controller)

The 4 selectable user data lengths are:

l

2 words process data; label 71

hex

(113)

PIW/POW 1

PIW/POW 2

Byte 1

Byte 2

Byte 3

Byte 4