4 status word, Status word, Parameter setting – Lenze 2131IB User Manual

Page 43

Advertising
background image

Parameter setting

6-20

BA2131EN

6.5.4

Status word

Note!

The current controller status can only be clarified by combining the bits with the status information
(bit 0, 1, 2, 3, 4, 5 and 6). This is shown in chapter 6.5.2.

Structure of the parameter “status word“:

Bit

Name

Meaning

0

Ready to switch on

Controller status information
0 = Status lower than “READY TO SWITCH ON“
1 = Status at least “READY TO SWITCH ON“

1

Switched on

Controller status information
0 = Status lower than “SWITCHED ON“
1 = Status at least “SWITCHED ON“

2

Operation enabled

Controller status information
0 = Status lower than “OPERATION ENABLED“
1 = Status “OPERATION ENABLED“

3

Fault

Controller status information
0 = No fault (TRIP))
1 = Fault (TRIP) occured

4

Voltage inhibited

Information on command “voltage inhibit“ (see chapter 6.5.3 “control word“)
0 = Command active
1 = Command not active

5

Quick stop

Information on command “quick stop“ (see chapter 6.5.3 “control word“)
0 = Command active
1 = Command not active

6

Switch-on inhibit

Controller status information
0 = Statu not “SWITCH-ON INHIBIT“
1 = Status “SWITCH-ON INHIBIT“

7

Warning

Collective warning
0 = No warning
1 = Warning (overtemperature)

8

Message

Collective message. Automatic setting and resetting of pulse inhibit in the controller status “OPERATION ENABLED“. Reasons for this
can be undervoltage or overvoltage as well as overcurrent (clamp) or malfunction configuration of 93xx.
0 = No message
1 = Message (IMP)

9

Remote

82XX:

Bus access, depends on Lenze parameter “operating mode“ (L-C0001):
0 = L-C0001

 3

1 = L-C0001

3

93XX:

1

10

FREE DRIVECOM:
Setpoint reached

Status of speed/frequency deviation
0 = RFG

on

 RFG

off

1 = RFG

on

= RFG

off

11

Limit value

Status of the DRIVECOM speed limitation
0 = Limitation not addressed
1 = Limitation addressed

12

FREE DRIVECOM:
Reserve

82XX:

Not assigned

93XX:

free. Mapping to bit L-C0150.B14

1)

13

FREE DRIVECOM:
Reserve

82XX:

Not assigned

93XX:

free. Mapping to bit L-C0150.B3

1)

14

Manufacturer

820X, 821X, 822X:

I

max

(current limit reached)

0 = Current limit not reached
1 = Current limit exceeded

8200 vector, 93XX:

free. Mapping to bit L-C0150.B2

1)

15

Manufacturer

820X, 821X, 822X:

Q

min

(f

d

$ f

dQmin

)

0 = Q

min

not active

1 = Q

min

active

8200 vector, 93XX:

free. Mapping to bit L-C0150.B5

1)

1)

For the assignment see the following table

Show/Hide Bookmarks