3 status word, Status word, Parameter setting – Lenze EMF2112IB User Manual

Page 39

Advertising
background image

Parameter setting

6-17

BA2112EN

Signal configuration C0005

Bit 15
(AIF-CTRL.B15)

Bit 14
(AIF-CTRL.B1
4)

Bit 13
(AIF-CTRL.B13)

Bit 12
(AIF-CTRL.B12)

Bit 11
(AIF-CTRL.B7)

Bit 6
(AIF-CTRL.B5)

Bit 5
(AIF-CTRL.B4)

vector control 1xx3 / 2xx3 / 3xx3

/ 5xx3 / 10xx3

NSET-RFG-STOP
(RFG stop)

NSET-RFG-0
(RFG zero)

Reserved

DCTRL-PAR*1

DCTRL-PAR-
LOAD

NSET-TI*1

NSET-TI*2

vector control 4xx3

NSET-RFG-STOP
(RFG stop)

NSET-RFG-0
(RFG zero)

Reserved

DCTRL-PAR*1

DCTRL-PAR-
LOAD

NSET-JOG*1

NSET-JOG*2

vector control 6xx3 / 7xx3 / 8xx3

/ 9xx3

Reserved

Reserved

Reserved

DCTRL-PAR*1

DCTRL-PAR-
LOAD

Reserved

Reserved

vector control 11xx3

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

6.1.3.3

Status word

Bit

Name

Meaning

0

Ready to switch on

Controller status information
0 = Status lower than “READY TO SWITCH ON“
1 = Status at least “SWITCHED ON“

1

Ready for operation

Controller status information
0 = Status lower than “READY FOR OPERATION“
1 = Status at least “READY FOR OPERATION“

2

Operation enabled

Controller status information
0 = Status lower than “OPERATION ENABLED“
1 = Status “OPERATION ENABLED“

3

Fault

Controller status information
0 = No fault (TRIP))
1 = Fault (TRIP) occured

4

Voltage inhibited

Information about command “Voltage inhibit“
0 = Command active
1 = Command not active

5

Quick stop

Information about command “QUICK STOP“
0 = Command active
1 = Command not active

6

Switch-on inhibit

Controller status information
0 = Status not “SWITCH-ON INHIBIT“
1 = Status “SWITCH-ON INHIBIT“

7

Warning

Collective warning
0 = No warning
1 = warning

8

Message

Collective message. Automatic setting and resetting of pulse inhibit in the controller status ”OPERATION ENABLED”. Reasons for
this can be undervoltage or overvoltage as well as overcurrent (clamp).
0 = No message
1 = Message (IMP)

9

Remote

82xx, 821x, 822x, 8200 vector:

Bus access right depends on Lenze parameter ”Operating mode” (C0001)

0 = C0001

3

1 = C0001 = 3

93XX:

DOZD\V 

10

Setpoint reached

Status of speed/frequency deviation
0 = RFG on

RFG off

1 = RFGon = RFGoff

11

Limit value

Status of the DRIVECOM speed limitation
always 0

12

Reserved

820X, 821X, 822X:

Reserved

8200 vector, 93XX:

Mapping to bit C0150.B14

13

Reserved

820X, 821x, 822x:

Reserved

8200 vector:

Mapping to bit C0150.B15

93XX:

Mapping to bit C0150.B3

14

Manufacturer

820X, 821x, 822x:

I max (current limit reached)

0 = Current limit not reached
1 = Current limit exceeded

8200 vector, 93XX:

Mapping to bit C0150.B2

15

Manufacturer

820X, 821x, 822x:

Q min (f d < dQmin )

0 = Q min not active
1 = Q min active

8200 vector, 93XX:

Mapping to bit C0150.B5

Show/Hide Bookmarks

Advertising